Trabuco Canyon Water District (TCWD)

Mar. 2024 - Current

On-Call, Maintenance, & Support Services

Project Team:

AIC, HydroTech

AIC Role:

System Integrator

Project Type:

Direct to Owner

Project Team:

Phil Serpas

CMMS/SCADA Administrator
949-241-4812
pserpas@tcwd.ca.gov
32003 Dove Canyon Dr. Trabuco Canyon, CA 92679

Key Project Elements:

  • AVEVA, InTouch & Historian SCADA
  • Inductive Automation, Ignition SCADA
  • Modicon M340/M580 PLCs
  • VMWare, virtualization
  • C-More OITs
  • Cisco/Palo Alto networking equipment
  • MDS Orbit radios
  • Proxim radios
  • Active Project Management
  • Task based scheduling and coordination
  • Field troubleshooting

AIC Team:

– David Estelle – Sr. Automation Engineer

– Kevin Ford – Project Manager

– Alex Valdez – Field Services Technician

– Jesus Lopez – Field Services Technician

– Nathan Vasquez – Automation Engineer

– Gintas Kazlauskas – Automation Engineer

– Alfonso Ducreux – EI&C Engineer

Summary:

Trabuco Canyon Water District (TCWD) provides water service, and in some cases reclaimed water service, recycled water service and waste water services, to applicants, customers and properties located within the District boundaries.

The District’s primary facilities is comprised of our Water Treatment Plant located in the City of Lake Forest, the Waste Water Treatment Plant located in the upper Robinson Ranch development, the Trabuco Creek Wells facility located in Trabuco Canyon, and our Administration Facility which located just outside the gates of Dove Canyon. In addition to the facility sites, TCWD has over 30 remotes with a challenging geographic topology.

TCWD was in need of a reliable and responsive System Integrator to provide task based and on-call support services for their Water system. Their needs included remote support four (4) hour response time & on-site support within a 24-hour mobilization.

Key Project Elements:

  • Controls network troubleshooting, including radios, routers, and firewalls. Including communication pack capture & interrogation
  • Software auto-dialer callout support and troubleshooting efforts within their virtualized SCADA architecture
  • Instrument validation including 4-20 mA spanning
  • Support with vendor RMA process for bad instrumentation
  • PLC development and field troubleshooting
  • Migration modernization from InTouch to Ignition. Our team fully tested the conversion efforts prior to onsite installation, performed system validation, & decommissioning of the legacy InTouch SCADA system
  • Process controls troubleshooting for both analyzers and control strategies